1 of 2 · FrontSmall-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline — Update 2022
In one breath
The 2022 update of the ESGE guideline on small-bowel capsule endoscopy (SBCE) and device-assisted enteroscopy (DAE) for the diagnosis and treatment of small-bowel disorders: 11 Main Recommendations covering suspected small-bowel bleeding, iron-deficiency anaemia, suspected Crohn's disease, retained foreign bodies, and pancreaticobiliary disease in surgically altered anatomy.
Back colours mark the reading sections — the chapter colour is the band and chip.
§1 · What it covers
This guideline covers SBCE and device-assisted enteroscopy in suspected small-bowel bleeding; iron-deficiency anaemia; suspected Crohn's disease (including patency capsule before SBCE in established Crohn's); SBCE after unremarkable or nondiagnostic dedicated small-bowel cross-sectional imaging; retained foreign bodies; and DAE-ERCP in surgically altered anatomy.
Applies to: Patients undergoing small-bowel investigation or therapy with capsule endoscopy or device-assisted enteroscopy.
§2 · Key recommendations
- MR1 — ESGE recommends small-bowel capsule endoscopy (SBCE) as the first-line investigation before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding. (Strong recommendation, moderate quality evidence).
- MR2 — ESGE recommends that SBCE be performed as soon as possible after the bleeding episode, optimally within 48 hours, to maximise diagnostic yield in overt suspected small-bowel bleeding. (Strong recommendation, high quality evidence).
- MR3 — ESGE recommends against routine second-look endoscopy before SBCE in suspected small-bowel bleeding or iron-deficiency anaemia. (Strong recommendation, low quality evidence).
- MR4 — ESGE recommends conservative management for patients with suspected small-bowel bleeding and a high quality negative SBCE. (Strong recommendation, moderate quality evidence).
- MR5 — ESGE recommends device-assisted enteroscopy (DAE) to confirm and possibly treat lesions identified by SBCE. (Strong recommendation, high quality evidence).
- MR6 — ESGE recommends SBCE as the first-line modality when small-bowel evaluation is indicated in iron-deficiency anaemia. (Strong recommendation, high quality evidence).
- MR7 — ESGE recommends SBCE as the initial diagnostic modality in suspected Crohn's disease with negative ileocolonoscopy, in the absence of obstructive symptoms or known stenosis. (Strong recommendation, high quality evidence).
- MR8 — ESGE recommends SBCE as a subsequent investigation in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, if deemed likely to influence patient management. (Strong recommendation, low quality evidence).
- MR9 — ESGE recommends use of a patency capsule before SBCE in established Crohn's disease, to decrease the capsule retention rate. (Strong recommendation, moderate quality evidence).
- MR10 — ESGE recommends DAE as an alternative to surgery for the retrieval of retained foreign bodies in patients without acute obstruction. (Strong recommendation, moderate quality evidence).