Strasberg's three criteria for conclusive identification of the cystic duct and cystic artery before anything is clipped or divided in laparoscopic cholecystectomy
M-327 · CVS — the Critical View of Safety
The expansion
1The hepatocystic triangle is cleared of fat and fibrous tissue (the common bile duct and common hepatic duct do not have to be exposed)
2The lower one third of the gallbladder is separated from the liver to expose the cystic plate
3Two and only two structures are seen entering the gallbladder
The SAGES Safe Cholecystectomy Program's six strategies for a universal culture of safety in cholecystectomy
M-333 · The SAGES Six Strategies
The expansion
1Use the Critical View of Safety (CVS) method of identification of the cystic duct and cystic artery during laparoscopic cholecystectomy
2Understand the potential for aberrant anatomy in all cases
3Make liberal use of cholangiography or other methods to image the biliary tree intraoperatively
4Consider an intra-operative momentary pause during laparoscopic cholecystectomy prior to clipping, cutting or transecting any ductal structures — a stop point to confirm the CVS has been achieved, using the doublet view
5Recognise when the dissection is approaching a zone of significant risk and halt the dissection before entering the zone — finish the operation by a safe method other than cholecystectomy if conditions around the gallbladder are too dangerous
6Get help from another surgeon when the dissection or conditions are difficult
Mishra's baseball-diamond concept of laparoscopic port position — the geometry a satisfactory port relationship must satisfy
M-336 · The Baseball Diamond
The expansion
TargetFirst decide the target — the optic and the two main operating ports are then laid out around it, usually at the points of a flattened triangle, the optic centrally and more distally placed
60°An angle of 60° between the two instrument tips — the manipulation angle; the telescope should be in the middle of the working instruments
TangentialTangential approach to the site
DistanceAppropriate working distance — half to two-thirds of the instrument inside the abdomen (arcs drawn at 18 cm and 24 cm from the target for the 36 cm adult instrument), and ports kept at least 5 cm apart